Metabolic Dysfunction-Associated Steatotic Liver Disease Diagnosis Using EfficientNet Transfer Learning and Ultrasound Images

Authors

  • Seyed Enayatallah Alavi Department of Computer Engineering, Shahid Chamran University of Ahvaz, Iran https://orcid.org/0000-0003-0495-5704
  • A'adel Sayyahi Department of Computer Engineering, Shahid Chamran University of Ahvaz, Iran https://orcid.org/0009-0005-3855-3430
  • Morteza Jaderyan Department of Computer Engineering, Shahid Chamran University of Ahvaz, Iran

DOI:

https://doi.org/10.47852/bonviewMEDIN620210151

Keywords:

metabolic dysfunction-associated steatotic liver disease, ultrasound images, EfficientNet, Mask R-CNN, Grey Wolf optimizer

Abstract

Metabolic dysfunction-associated fatty liver disease (MASLD) is a prevalent, progressive hepatic disorder affecting approximately 30% of the population in developed countries, underscoring the need for rapid, accurate, noninvasive diagnostic tools. Ultrasound imaging remains a primary diagnostic modality; however, patient privacy is addressed directly in this work. This study presents a privacy-aware deep learning framework for detecting MASLD from ultrasound images. Given an initial dataset of only 55 images, extensive enhancement (rotation, brightness and contrast adjustment, and CLAHE) was applied to expand the training dataset to 1550 samples. To preserve patient privacy, a Mask R-CNN model was used to detect and remove foreign and potentially identifying objects from the images before processing. Subsequently, the image quality was enhanced through a homomorphic filter based on the gray wolf optimizer, which suppressed speckle noise and achieved a peak signal-to-noise ratio of 72.9 dB. The pre-trained EfficientNet network (B0-B7 and V2-S, V2-M, V2-L) was evaluated as a transfer learning backbone for 2-class classification tasks: binary discrimination between normal and fatty liver, and 4-class grading (Normal; grades I-III). EfficientNetB6 achieved 100% classification accuracy with an area under the curve (AUC) of 1.0 in the binary task, while EfficientNetB5, B6, and B7 each achieved 99.87% accuracy in the 4-class task, with EfficientNetB5 having the highest AUC of 0.9994. By simultaneously achieving diagnostic accuracy and privacy preservation, the proposed framework establishes a robust and clinically applicable approach for early diagnosis of MASLD.

 

Received: 26 April 2026 | Revised: 17 August 2026 | Accepted: 11 November 2026

 

Conflicts of Interest

The authors declare that they have no conflicts of interest to this work.

 

Data Availability Statement

The liver ultrasound image dataset used in this study is publicly available on the Zenodo archive (https://doi.org/10.5281/zenodo.1009146) under the CC BY 4.0 license. The data can be accessed through the reference provided in the bibliography.

 

Author Contribution Statement

A’adel Sayyahi: Conceptualization, Methodology, Software, Formal analysis, Investigation, Data curation, Writingoriginal draft, Writing - review & editing, Visualization. Seyed Enayatallah Alavi: Conceptualization, Methodology, Validation, Resources, Supervision, Project administration. Morteza Jaderyan: Conceptualization, Methodology, Validation, Resources, Supervision.

Downloads

Published

2026-11-26

Issue

Section

Research Articles

How to Cite

Enayatallah Alavi, S., Sayyahi, A., & Jaderyan, M. (2026). Metabolic Dysfunction-Associated Steatotic Liver Disease Diagnosis Using EfficientNet Transfer Learning and Ultrasound Images. Medinformatics. https://doi.org/10.47852/bonviewMEDIN620210151